BIOCONSERVACION S.A.U.– C/ Vapor 12. P.I. El Regàs 08850 Gavà (Barcelona), Spain

Tel: +34 93 662 32 54 | info@bioconservacion.com

Corrosion Control in the Paper Industry

2022-09-15 12:35:46

It is a fact that corrosion has a significant economic impact on an industrial scale. As an example, the results of a study carried out in the USA showed that the estimated annual cost due to corrosion was $276 million, which is approximately 3.1% of the country's gross domestic product (GDP). It is logical then that, during the last decades, great efforts have been invested to face this problem and significantly improve corrosion management, offering better solutions, better equipment and new materials adapted for this purpose.

 

But what do we mean by "corrosion"? It can be defined in many ways, among the different meanings, we could say that corrosion can be the deterioration of materials by chemical interaction with their environment. Although the term corrosion is sometimes also applied to the degradation of plastics, concrete and wood, but in general it refers to metals.

 

The main problem is corrosion occurring in large industrial plants, such as power plants or chemical processing plants, where corrosion can even lead to plant shutdowns and/or production stoppages, with the economic consequences that this entails.

In particular, the paper industry is one of the industries most susceptible to this problem, which is why they invest in systems to reduce and control corrosion levels.

 

Project Description

 

BION has extensive experience in this sector and in recent years has improved the solutions suggested to avoid equipment failures due to corrosion. In the last 4 years Bioconservacion has supplied a mixture composed of BION ISORB and BION DOD to a pulp and paper plant located in Uruguay, specifically at the UPM plant in Fray Bentos. This plant is located on the banks of the Uruguay River, 4 km east of the city of Fray Bentos in the province of Rio Negro, and has a production capacity of 1.3 million tons per year of bleached eucalyptus short-fiber pulp for the manufacture of glossy paper and tissue paper.

 

PBS (Parallel Bed Scrubber) equipment was installed in this plant to prevent the deterioration of electrical components due to corrosion. The PBS equipment is a system similar to a SAH equipment, where the filter media are packed in bulk instead of using modules. This type of system can treat horizontal flows between 425 and 54,000 m3/h. On this occasion, the installed equipment is composed of two treatment stages, each with specific filter media in order to obtain maximum efficiency in the elimination of complex air emission.

 

After studying the composition of the main pollutants present in the installation, Bioconservacion suggested two filter media, which in combination can successfully remove most of the problematic compounds present in the stream. This specific mixture is composed of BION ISORB and BION DOD.

 

BION ISORB is designed to successfully attack a wide range of gases. It is especially recommended for the control of acid gases, nitrogen containing compounds, sulfur compounds and low molecular weight gases. BION ISORB uses a combination of two processes for contaminant removal. One of a physical nature, trapping the molecules inside the pellet due to its large internal surface area and a second by chemical oxidation. The oxidized gases are converted into harmless products. A particularity of BION ISORB is that it maintains its effectiveness even in the treatment of streams with relative humidity contents up to values above 95%.

 

This filter media is commonly used in applications such as wastewater treatment plants, pulp and paper plants, airports, chemical plants, refineries or laser cutting and engraving plants.

 

In turn, BION DOD is a high purity, high surface area, bi-impregnated activated carbon that effectively neutralizes acids.

 

BION DOD is a filter media widely used in water treatment plants, it has a very high H2S absorption capacity and is very useful for the treatment of mercaptans and other volatile organic compounds. It is a filter media especially suitable for neutralizing acidic compounds.

 

Evaluation

 

UPM Fray Bentos has been working with this PBS equipment and BION ISORB and BION DOD filter media to effectively prevent corrosion for 4 years. The client has been able to extend the life of its equipment and save costs due to maintenance shutdowns.

 

Bioconservacion also offers the service of performing an analysis of the remaining life of the filtering granulates, halfway through their estimated life, in order to re-optimize the replacement of the granulate mixture in the event that the actual working conditions differ from the initial conditions taken into account in the characterization.

In our blog...

Protect your biogas installations and reduce the maintenance costs

The conversion of biogas into green energy is not only environmentally friendly, but also contributes to the optimization of natural resources. More and more industries have biogas stations to take advantage of waste generated in these facilities, contributing to generate a circular economy where all available resources are exploited.   Biogas plants need to remove impurities before it is diverted to its final use (upgrading or cogeneration engines). In the case of upgrading, the need for purification is high due to the strict conditions required for methane purity.   The BION media ensures an effective removal of impurities at 99.5% efficiency.   BION medias: Protect and maintain the compressor by preventing the occurrence of corrosive atmosphere inside the compressor. Protect the membranes against fouling or pore blockage. Have very high adsorption capacity They are specially designed to give high performance in environments with low oxygen levels. Protect and maintain the installations   This becomes to reduced operating and maintenance costs and increased sorbent or adsorbent lifetime.   BION biogas purification solutions are the best return on investment because they They remove pollutant gases before they cause irreversible damage to membranes, compressors or cogeneration equipment. Enables compliance with biomethane grid injection input requirements Extends the lifetime of the pretreatment stage by reducing operating costs Avoid downtime by preventing costly unexpected repairs Eliminate ALL common contaminants other than H2S.

READ MORE »

WWTPs, how to prevent and control the generation of odorous gases?

There are three commonly used technologies for the prevention and control of odor gases: 1: chemical scrubbing The chemical scrubbing treatment system consists of passing the gas through scrubbing towers where air/water/reagent contact takes place. In chemical scrubbing, an acidic or basic chemical solution is injected into the system from the top, passing through the flow of the gas, and is then recovered at the bottom of the tower for recovery and recirculation. The gaseous compounds are retained in the chemical solution which must be replaced periodically.   This technology has a high operating cost and a high risk associated because of the handling of this kind of chemicals.   2: filtration with solid adsorbents There are different types of solid adsorbents for odor removal, the most common is activated carbon. The gas passes through tanks containing the adsorbent media. The adsorbent media and its ability to remove odorous gases can vary depending on: - The porous structure of the base material (activated carbon, natural clays). - The chemical impregnation of the agents that cause the adsorbent media to react with specific gaseous contaminants to retain them or convert them into non-odorous ones.   Activated carbon filtration is a technology with a low initial investment cost, which does not require qualified personnel for its operation, which makes its use extensive.   The installation of covers in different areas of the wastewater or sewage treatment plant (pretreatment, thickeners, sludge storage, decanter channels (1st and 2nd), allow to mitigate the dispersion of odorous gases and to channel the air flow towards a tank with adsorbent media that allows the filtration of odor causing compounds (H2S, ammonia, sulfides, mercaptans, VOCs).   BION offer solutions consisting of adsorbent media or chemical filter media (https://www.bioconservacion.com/chemical-filtration-media). These solutions include virgin activated carbon and other adsorbent chemical media that effectively remove odor gases generated in a WWTP even better and more efficiently than activated carbon solutions.   3: advanced biofiltration (biofilters) The biofiltration deodorization process is based on the action of microorganisms capable of decomposing odorous compounds. They are effective when it is necessary to remove high concentrations of odor compounds or to treat large air flows. The operating cost is minimal. But microorganisms are sensitive to atmospheric conditions of temperature and relative humidity. Also need a constant supply to survive. It can be affected by process stoppages or decreases in the concentration of the compounds reaching the filter.   Each of these systems has its own characteristics, advantages and disadvantages. The most appropriate technology will depend, to a large extent, on the type of gaseous effluent to be treated.

READ MORE »

Safety and Corrosion Protection in Refineries

The environment in a refinery is highly corrosive, which makes it necessary to implement control systems not only to protect people but also the equipment that controls the processes to ensure their reliability.   Bioconservacion has equipment specially designed for the safety of people, to protect against corrosion in control rooms and cabinet pressurization equipment. Some CEPSA refineries in Spain have installed some of this equipment.   Specifically, the CEPSA Gibraltar San Roque refinery in Cadiz was equipped with a packed bed system for personal safety, specifically a Packed Bed System (PBS).   The packed bed system includes the following filters: - G4 particulate filter, this is a pre-filter that collects dust and traps larger particles, protecting grids and granulates. - Vertical beds, the air passes through the holes in the perforated plate and passes through the BION filter media, which are determined according to the pollutants to be treated.  The filling of these vertical beds is a relatively simple job. No tools or highly skilled specialists are required. - Final particulate filter type F7, this is a higher efficiency filter for particulate removal. The equipment has to protect a room of 155 cubic meters where, if necessary, seven to nine people would be accommodated for a time of 20 to 30 minutes. This time should be achieved with two different contamination scenarios: - Scenario 1, 10280.00 mg/m3 SH2 80%+various hydrocarbons 20%. - Scenario 2, 10900.00 mg/m3 HF.  The CEPSA Tenerife refinery has installed a UPP (Positive Pressurization Unit) where part of the outside air is taken, cleaned and pressurized in a control room of about 60 square meters. Additionally, a part of the air is used to re-circulate and clean the air from possible indoor contaminants and door openings.   It is designed to provide positive pressurization with air free of corrosive gases in environments containing computers, control rooms, motor control centers and electronic or electrical equipment.   There are two types of configurations: horizontal and vertical. However, the equipment is tailor-made according to the customer's particular needs and desired specification.   There are different filter media to remove various types of gases. The most common are: hydrogen sulfide, sulfur dioxide, nitrogen oxides, chlorine compounds and ammonia.   In the refinery there is a set of transformers that switch from 220 to 110 v. The electrical cabinet pressurization equipment installed there must meet two requirements: it must be sufficiently ventilated so that the equipment does not heat up and the air introduced into it must be cleaned.   Bioconservacion has a fully equipped laboratory to ensure good corrosion control. By analyzing coupons, corrosive agents are characterized and the aggressiveness of the environment is classified according to the ISA 71.04 standard.   The laboratory is also capable of measuring the remaining life of filter media, a service it offers to its customers to ensure timely replacement of media.        